Microscopy at the Bottom
August 30, 2009 – At the Microscopy Conference MC2009 in Graz, Ulm University sets out why aberration correction alone is not enough at the bottom of the length scale. On an FEI Titan, a carbon nanotube dies within 10 s at 300 kV but survives 20 min at 80 kV, and only the Cs corrector resolves it there. In single-layer graphene, a short 300 kV pulse removes about ten atoms and the lattice reconstructs; between growing holes, ribbons thin into chains of single carbon atoms. AIST in Tsukuba, Berkeley and Oxford see the same with three other corrected microscopes. The next step named: low voltage with a Cc corrector, the aim of SALVE.
Fifty years after Richard Feynman’s talk “There’s Plenty of Room at the Bottom”, researchers at Ulm University take stock of what aberration-corrected transmission electron microscopy can do at the bottom of the length scale, and of what still stands in the way. In their contribution to the Microscopy Conference MC2009 in Graz, Ute Kaiser, Andrey Chuvilin, Jannik Meyer and Johannes Biskupek show with an FEI Titan 80-300 why the correction of spherical aberration alone is not enough for light materials. At 300 kV, the beam destroys a carbon nanotube within ten seconds; at 80 kV, the same kind of tube survives twenty minutes, and only the corrector resolves its lattice. On single-layer graphene, the team removes about ten atoms with a short pulse at 300 kV and watches the lattice reconstruct, and between growing holes it finds ribbons that thin down to chains of single carbon atoms. The paper sets out the programme of the SALVE project: to image beam-sensitive materials on graphene, below their damage threshold, with a microscope corrected also for chromatic aberration.
One hundred times too poor
For decades, the Scherzer theorem set the limit: round electromagnetic lenses always have large spherical and chromatic aberrations, so the resolution of an electron microscope stays at about a hundred times the electron wavelength[1]. Feynman put it in 1959: it would be easy to analyse any complicated chemical substance by looking where the atoms are, “the only trouble is that the electron microscope is one hundred times too poor”[2]. Since the only remedy was a shorter wavelength, microscopes moved to higher voltages, but even thick crystals survive a MeV beam for only a few minutes[3].
The way out came with lenses that are not round. Harald Rose designed the first corrector that could compensate the spherical aberration Cs of the objective lens[4]; it was realized for TEM in 1998[5] and for STEM in 1999[6] and became commercial in 2005. With negative Cs and over-focus, the so-called NCSI conditions, atoms appear white on a dark background, which helps to see light atoms next to heavy ones[7],[8]. The Ulm team itself used such conditions to image all atomic columns of β-Si3N4, with dumbbells down to 78 pm at 300 kV[9].
Resolution limited by the sample
With a corrector, the microscope is no longer the weakest link. In a real experiment, the sample sets a second limit: the electron dose it tolerates, and with it the contrast and signal-to-noise ratio that can be collected before it changes[10]. Many carbon materials are destroyed at once at 300 kV. Fig. 1 shows a single-walled carbon nanotube on carbon soot after ten seconds at 300 kV and after twenty minutes at 80 kV; at 80 kV, the lattice is clearly resolved and the contrast of the soot is much stronger[11]. The two voltages are compared in the box below.
Lowering the voltage alone does not give atomic resolution, because the spherical aberration then blurs the image even more. At 80 kV, the walls of a double-walled nanotube are resolved only with the corrector, as the box below shows with both images (Fig. 2).
Four ways to damage a sample
The tolerable dose is set by four processes: knock-on damage, ionisation, heating, and chemical etching by molecules left in the vacuum. For nanocarbons, knock-on at the surface dominates, because nearly every atom is a surface atom. The threshold for knocking out a surface atom lies well below that of the bulk: 140 kV for graphite[16], below 90 kV for carbon in a nanotube[17]. Knock-on is the only one of the four that decreases with the voltage. The other three increase, because inelastic scattering grows as the electrons slow down; for EDX and EELS, the same fact is welcome, since it strengthens their signals.
Each mechanism has its own remedy, collected in the box below. The most striking is the role of heat (Fig. 3): fullerenes with dysprosium atoms inside two neighbouring nanotubes, exposed to the same dose, behave very differently depending on how well each tube touches the grid.
Atoms knocked out on purpose
Graphene shows what an 80 kV corrected microscope can already do with single carbon atoms. In Fig. 4, a brief exposure at 300 kV with a dose of 107 electrons per nm2 has removed about ten atoms from a single layer. The result is not a set of simple vacancies: an area of about 1 nm has reconstructed around the missing atoms, and all carbon atoms remain in a planar sp2 network. Such reconstructed defects are rather stable in clean areas, and the authors suggest that artificial defects could later serve as anchor points for adsorbates of low contrast.
From ribbons to chains
Perfectly clean graphene could not yet be prepared[15]. Contamination is always present, and it is exactly there that holes start to grow under the 80 kV beam. Between two holes, a graphene ribbon remains, and after a while it thins into a chain of single carbon atoms[20] (see Graphene: Chains and Edges[21]). The chains turned out to be surprisingly stable under the beam. None showed a zigzag shape, so they must be one of the two linear forms, cumulene with double bonds or polyyne with alternating single and triple bonds; which one exists depends on whether the number of atoms is even or odd[22].
The results stand next to those of three other groups that imaged graphene in the same year with other corrected microscopes, at AIST in Tsukuba, in Berkeley and in Oxford. They are compared in the boxes below, after the comparison of the Ulm observations with the knock-on picture.
The first group, at AIST in Tsukuba, made carbon chains from graphene in the same way at 120 kV; the box below shows a chain from each microscope at the same scale (Fig. 5).
In Berkeley, the edges of growing holes were filmed at 80 kV; the next box sets a hole from each laboratory side by side (Fig. 6).
Oxford, finally, watched defects and edges in graphene reconstruct in real time; the last box compares a defect from Oxford with the one from Ulm (Fig. 7).
Challenges named by the authors
The authors name the limits of their own experiments. The signal-to-noise ratio was not sufficient to count the atoms in the chains reliably, so the chain type remains open. Graphene is never perfectly clean, and holes start exactly at the contamination. To which extent species other than water contribute to the etching remains to be investigated. Using graphene as a low-noise substrate, where beam-sensitive material could be imaged as if it were free-standing after subtracting the lattice, will need even lower voltages and higher resolution than are currently possible. And at low voltage, correcting Cs is not enough: the chromatic aberration Cc of the objective lens then limits the resolution, and a hexapole corrector cannot correct it.
Room at the bottom
For the next step, the authors point to a new corrector design of symmetric multipole quintuplets that corrects both Cs and Cc without adding higher-order aberrations[26],[27]. Conducting solids such as metals and nanocarbons would profit directly. For insulators and organic materials, ionisation damage and contrast both rise as the voltage drops, but experiments show that the contrast rises faster[28], so the signal-to-noise ratio should improve. “The beneficial features of low-voltage TEM are the elimination of knock-on damage and the increase of contrast, S/N and increase of inelastic signals,” the authors conclude. Single-layer membranes such as graphene and boron nitride[29] (see Boron Nitride Membranes[30]) are the natural first samples.
Resource:
Kaiser, U., Chuvilin, A., Meyer, J. C., Biskupek, J. (2009).
Microscopy at the Bottom.
MC2009 Proc., Vol. 3 3, 379–384.
https://doi.org/10.3217/978-3-85125-062-6-379
Update – September 28, 2009
The news article of August 30, 2009 ends above. Later work is listed below.
The SALVE microscope outlined
A month after the conference, Harald Rose, who had designed the first Cs corrector, set out the electron optics behind this programme in the Philosophical Transactions of the Royal Society A[31]. Graphite and nanotubes, whose surface atoms are bound by about 10 eV, are not damaged by knock-on below roughly 60 kV, and for most materials of light atoms the threshold for surface etching lies well below 100 kV. Atomic resolution at such voltages, with many equally resolved image points, needs an achromatic aplanat: a lens system free of chromatic and spherical aberration and of off-axial coma. Rose proposes a coma-free objective lens of two windings with opposite currents, combined with the corrector of the TEAM project, which replaces each hexapole of his 1990 design by a multipole quintuplet: electric and magnetic quadrupoles compensate Cc, octopoles Cs, for voltages of about 20 to 100 kV. An obstruction-free phase plate shifts the phase of the scattered wave so that phase contrast and scattering contrast add up. “The realization of such a microscope is the aim of the SALVE (Sub-Å Low-Voltage Electron microscope) project proposed by Ute Kaiser,” Rose writes. Like the Ulm paper, he expects conducting materials such as metals and nanotubes to profit most, and insulators and organic materials too, because contrast rises faster than damage as the voltage drops.
Update – April 1, 2011
A first microscope at 20 kV
Ulm, CEOS, Carl Zeiss, Vienna and Nottingham characterized the prototype of the SALVE microscope, a monochromated Zeiss Libra 200 with a CEOS Cs corrector, at only 20 kV[32] (see TEM at 20 kV[33]). It resolved 213 pm lattice fringes in single-layer graphene, and C60 fullerenes inside a nanotube withstood about a hundred times the dose that destroys them at 80 kV. Chromatic aberration set the limit, as predicted in 2009.
Update – May 7, 2012
The knock-on threshold measured
Ulm and partners counted, atom by atom, how many carbon atoms the beam removes from graphene at 80–100 kV and made the first accurate measurement of the displacement cross section[34] (see Knock-on Damage in Graphene Linked to Lattice Vibrations[35]). Damage sets in just above 80 kV, although a static calculation puts the threshold near 108 kV: the vibrations of the lattice explain the difference.
Update – November 13, 2013
The graphene sandwich
The sandwich proposed in 2009 was realized in Ulm with monolayer MoS2 between two graphene sheets[36] (see MoS2 Encapsulated in Graphene[37]). At 80 kV on the FEI Titan, the encapsulation raised the radiation tolerance of MoS2 by nearly three orders of magnitude.
Update – August 9, 2016
Cc corrected from 20 to 80 kV
CEOS, FEI (today Thermo Fisher Scientific) and Ulm put into operation the corrector called for in 2009, which removes both Cs and Cc[38] (see SALVE Cc Correction Realized[39]). The SALVE III microscope resolves atoms at every voltage from 20 to 80 kV, with an information limit of 90 pm at 40 kV.
Download this news article as PDF – for reading on paper, taking notes or filing.
-
Scherzer, O. (1936). Über einige Fehler von Elektronenlinsen. Z. Phys., 101, 593–603. https://doi.org/10.1007/BF01349606
-
Feynman, R. P. (1959). There’s Plenty of Room at the Bottom. Talk at the annual meeting of the American Physical Society, California Institute of Technology, 29 December 1959.
-
Dehm, G., Nadarzinski, K., Ernst, F., Rühle, M. (1996). Quantification of Irradiation Damage Generated During HRTEM With 1250 keV Electrons. Ultramicroscopy, 63, 49–55. https://doi.org/10.1016/0304-3991(96)00025-3
-
Rose, H. (1990). Outline of a Spherically Corrected Semiaplanatic Medium-Voltage Transmission Electron Microscope. Optik, 85, 19–24.
-
Haider, M., Uhlemann, S., Schwan, E., Rose, H., Kabius, B., Urban, K. (1998). Electron Microscopy Image Enhanced. Nature, 392, 768–769. https://doi.org/10.1038/33823
-
Krivanek, O. L., Dellby, N., Lupini, A. R. (1999). Towards Sub-Å Electron Beams. Ultramicroscopy, 78, 1–11. https://doi.org/10.1016/S0304-3991(99)00013-3
-
Jia, C. L., Lentzen, M., Urban, K. (2003). Atomic-Resolution Imaging of Oxygen in Perovskite Ceramics. Science, 299, 870–873. https://doi.org/10.1126/science.1079121
-
Lentzen, M., Jahnen, B., Jia, C. L., Thust, A., Tillmann, K., Urban, K. (2002). High-Resolution Imaging With an Aberration-Corrected Transmission Electron Microscope. Ultramicroscopy, 92, 233–242. https://doi.org/10.1016/S0304-3991(02)00139-0
-
Zhang, Z., Kaiser, U. (2009). Structural Imaging of β-Si3N4 by Spherical Aberration-Corrected High-Resolution Transmission Electron Microscopy. Ultramicroscopy, 109, 1114–1120. https://doi.org/10.1016/j.ultramic.2009.04.004
-
Rose, H. (2007). Criteria and Prospects for Realizing Optimum Electron Microscopes. Microsc. Microanal., 13, 134–135. https://doi.org/10.1017/S1431927607071358
-
Malac, M., Beleggia, M., Egerton, R., Zhu, Y. (2007). Bright-Field TEM Imaging of Single Molecules: Dream or Near Future? Ultramicroscopy, 107, 40–49. https://doi.org/10.1016/j.ultramic.2006.05.001
-
Meyer, J. C., Kisielowski, C., Erni, R., Rossell, M. D., Crommie, M. F., Zettl, A. (2008). Direct Imaging of Lattice Atoms and Topological Defects in Graphene Membranes. Nano Lett., 8, 3582–3586. https://doi.org/10.1021/nl801386m
-
Warner, J. H., Ito, Y., Rümmeli, M. H., Gemming, T., Büchner, B., Shinohara, H., Briggs, G. A. D. (2009). One-Dimensional Confined Motion of Single Metal Atoms Inside Double-Walled Carbon Nanotubes. Phys. Rev. Lett., 102, 195504. https://doi.org/10.1103/PhysRevLett.102.195504
-
Chuvilin, A., Khlobystov, A. N., Obergfell, D., Haluska, M., Yang, S., Roth, S., Kaiser, U. (2010). Observations of Chemical Reactions at the Atomic Scale: Dynamics of Metal-Mediated Fullerene Coalescence and Nanotube Rupture. Angew. Chem. Int. Ed., 49, 193–196 (submitted 2009). https://doi.org/10.1002/anie.200902243
-
Meyer, J. C., Girit, C. O., Crommie, M. F., Zettl, A. (2008). Hydrocarbon Lithography on Graphene Membranes. Appl. Phys. Lett., 92, 123110. https://doi.org/10.1063/1.2901147
-
Egerton, R. F., Li, P., Malac, M. (2004). Radiation Damage in the TEM and SEM. Micron, 35, 399–409. https://doi.org/10.1016/j.micron.2004.02.003
-
Zobelli, A., Gloter, A., Ewels, C. P., Seifert, G., Colliex, C. (2007). Electron Knock-on Cross Section of Carbon and Boron Nitride Nanotubes. Phys. Rev. B, 75, 245402. https://doi.org/10.1103/PhysRevB.75.245402
-
Liu, Z., Yanagi, K., Suenaga, K., Kataura, H., Iijima, S. (2007). Imaging the Dynamic Behaviour of Individual Retinal Chromophores Confined Inside Carbon Nanotubes. Nat. Nanotechnol., 2, 422–425. https://doi.org/10.1038/nnano.2007.187
-
Mølhave, K., Gudnason, S. B., Pedersen, A. T., Clausen, C. H., Horsewell, A., Bøggild, P. (2007). Electron Irradiation-Induced Destruction of Carbon Nanotubes in Electron Microscopes. Ultramicroscopy, 108, 52–57. https://doi.org/10.1016/j.ultramic.2007.03.001
-
Chuvilin, A., Meyer, J. C., Algara-Siller, G., Kaiser, U. (2009). From Graphene Constrictions to Single Carbon Chains. New J. Phys., 11, 083019. https://doi.org/10.1088/1367-2630/11/8/083019
-
SALVE news (2009). Graphene: Chains and Edges. salve-project.de, August 19, 2009. https://salve-project.de/newspress/formation-of-linear-carbon-chains.html
-
Bodart, V. P., Delhalle, J., Dory, M., Fripiat, J. G., André, J.-M. (1987). Finite Hydrocarbon Chains Incorporating Cumulenic Structures: Prediction by Ab Initio Calculations of Large Static Polarizabilities. J. Opt. Soc. Am. B, 4, 1047–1054. https://doi.org/10.1364/JOSAB.4.001047
-
Jin, C., Lan, H., Peng, L., Suenaga, K., Iijima, S. (2009). Deriving Carbon Atomic Chains From Graphene. Phys. Rev. Lett., 102, 205501. https://doi.org/10.1103/PhysRevLett.102.205501
-
Girit, Ç. Ö., Meyer, J. C., Erni, R., et al. (2009). Graphene at the Edge: Stability and Dynamics. Science, 323, 1705–1708. https://doi.org/10.1126/science.1166999
-
Warner, J. H., Rümmeli, M. H., Ge, L., Gemming, T., Montanari, B., Harrison, N. M., Büchner, B., Briggs, G. A. D. (2009). Structural Transformations in Graphene Studied With High Spatial and Temporal Resolution. Nat. Nanotechnol., 4, 500–504. https://doi.org/10.1038/nnano.2009.194
-
Rose, H. (2004). Outline of an Ultracorrector Compensating for All Primary Chromatic and Geometrical Aberrations of Charged-Particle Lenses. Nucl. Instrum. Methods Phys. Res. A, 519, 12–27. https://doi.org/10.1016/j.nima.2003.11.115
-
Haider, M., Müller, H., Uhlemann, S., Zach, J., Loebau, U., Hoeschen, R. (2008). Prerequisites for a Cc/Cs-Corrected Ultrahigh-Resolution TEM. Ultramicroscopy, 108, 167–178. https://doi.org/10.1016/j.ultramic.2007.07.007
-
Hayashida, M., Kawasaki, T., Kimura, Y., Takai, Y. (2006). Estimation of Suitable Condition for Observing Copper–Phthalocyanine Crystalline Film by Transmission Electron Microscopy. Nucl. Instrum. Methods Phys. Res. B, 248, 273–278. https://doi.org/10.1016/j.nimb.2006.04.168
-
Meyer, J. C., Chuvilin, A., Algara-Siller, G., Biskupek, J., Kaiser, U. (2009). Selective Sputtering and Atomic Resolution Imaging of Atomically Thin Boron Nitride Membranes. Nano Lett., 9, 2683–2689. https://doi.org/10.1021/nl9011497
-
SALVE news (2009). Boron Nitride Membranes. salve-project.de, May 29, 2009. https://salve-project.de/newspress/boron-nitride-membranes.html
-
Rose, H. H. (2009). Future Trends in Aberration-Corrected Electron Microscopy. Phil. Trans. R. Soc. A, 367, 3809–3823. https://doi.org/10.1098/rsta.2009.0062
-
Kaiser, U., Biskupek, J., Meyer, J. C., et al. (2011). Transmission Electron Microscopy at 20 kV for Imaging and Spectroscopy. Ultramicroscopy, 111, 1239–1246. https://doi.org/10.1016/j.ultramic.2011.03.012
-
SALVE news (2011). TEM at 20 kV. salve-project.de, April 1, 2011. https://salve-project.de/newspress/transmission-electron-microscopy-at-20-kv.html
-
Meyer, J. C., Eder, F., Kurasch, S., et al. (2012). Accurate Measurement of Electron Beam Induced Displacement Cross Sections for Single-Layer Graphene. Phys. Rev. Lett., 108, 196102. https://doi.org/10.1103/PhysRevLett.108.196102
-
SALVE news (2012). Knock-on Damage in Graphene Linked to Lattice Vibrations. salve-project.de, May 7, 2012. https://salve-project.de/newspress/knock-on-damage-in-graphene-linked-to-lattice-vibrations.html
-
Algara-Siller, G., Kurasch, S., Sedighi, M., Lehtinen, O., Kaiser, U. (2013). The Pristine Atomic Structure of MoS2 Monolayer Protected From Electron Radiation Damage by Graphene. Appl. Phys. Lett., 103, 203107. https://doi.org/10.1063/1.4830036
-
SALVE news (2013). MoS2 Encapsulated in Graphene. salve-project.de, November 13, 2013. https://salve-project.de/newspress/encapsulation-mos2-in-graphene-controlling-radiation-damage.html
-
Linck, M., Hartel, P., Uhlemann, S., et al. (2016). Chromatic Aberration Correction for Atomic Resolution TEM Imaging From 20 to 80 kV. Phys. Rev. Lett., 117, 076101. https://doi.org/10.1103/PhysRevLett.117.076101
-
SALVE news (2016). SALVE Cc Correction Realized. salve-project.de, August 9, 2016. https://salve-project.de/newspress/SALVE-CC-correction-realized.html







